Noco Genius10 Smart Charger User Guide

About GENIUS10.

The NOCO GENIUS10 represents some of the most innovative and advanced technology on the market, making each charge simple and easy. It is quite possibly the safest and most efficient charger you will ever use. The GENIUS10 is designed for charging all types of 6V & 12V lead-acid batteries, including Lithium (LiFePO4), Wet (Flooded), Gel, MF (Maintenance-Free), CA (Calcium), EFB (Enhanced Flooded Battery), and AGM (Absorption Glass Mat) batteries. It is suitable for charging battery capacities up to 230 Amp-Hours and maintaining all battery sizes.

Getting Started. Before using the charger, carefully read the battery manufacturer’s specific precautions and recommended rates of charge for the battery. Make sure to determine the voltage and chemistry of the battery by referring to your battery owner’s manual prior to charging.

Technical specifications

Input Voltage AC: 120-240 VAC, 50-60Hz
Working Voltage AC: 120-240 VAC, 50-60Hz
Output Power: 150 W Max
Charging Voltage: Various
Charging Current: 10A (12V), 10A (6V))
Low-Voltage Detection: 1V (12V), 1V (6V)
Back Current Drain: <0.5mA
Ambient Temperature: -20°C to +40°C
Type of Batteries: 6V, 12V
Battery Chemistries: Wet, Gel, MF, CA, EFB, AGM, Calcium, Lithium
Battery Capacity: Up to 230Ah, Maintains All Battery Sizes
Housing Protection: IP65
Cooling: Natural Convection
Dimensions (L x W x H): 7.1 x 3.6 x 2.3 Inches
Weight: 3.33 Pounds

How to Use Noco Genius10

Charging Modes.
The GENIUS10 has nine (9) modes: Standby, 12V, 12V AGM, 12V LITHIUM, 6V, 6V AGM, REPAIR, SUPPLY and Force. Some charge modes must be pressed and held for three (3) to five (5) seconds to enter the mode. These “Press and Hold” modes are advanced charging modes that require your full attention before selecting. It is important to understand the differences and purpose of each charge mode. Do not operate the charger until you confirm the appropriate charge mode for your battery. 

Using 6V. [Press & Hold for 3 seconds]
6V charge mode is designed for 6-volt lead-acid batteries only, like Wet Cell, Gel Cell, Enhanced Flooded, Maintenance-Free and Calcium batteries. Press and hold for three (3) seconds to enter 6V Charge Mode. Consult the battery manufacturer before using this mode.

Using 12V Lithium.
12V Lithium charge mode is designed for 12-volt lithium-ion batteries only, including lithium iron phosphate.
CAUTION. USE THIS MODE WITH EXTREME CARE. THIS MODE SHOULD ONLY BE USED WITH 12-VOLT LITHIUM BATTERIES THAT HAVE A BUILT-IN BATTERY MANAGEMENT SYSTEM (BMS). LITHIUM-ION BATTERIES ARE MADE AND CONSTRUCTED IN DIFFERENT WAYS AND SOME MAY OR MAY NOT CONTAIN A BATTERY MANAGEMENT SYSTEM (BMS). CONSULT THE LITHIUM BATTERY MANUFACTURER BEFORE CHARGING AND ASK FOR RECOMMENDED CHARGING RATES AND VOLTAGES. SOME LITHIUM-ION BATTERIES MAY BE UNSTABLE AND UNSUITABLE FOR CHARGING.

Using 13.6V Supply. [Press and Hold 3 Seconds With Clamps Not Connected]
13.6V Supply converts the charger to a constant current, constant voltage DC power supply. It can be used to power 12VDC devices, tire inflators, seat heaters and more. As a power supply, it can also be used to retain a vehicle’s on-board computer settings during battery repair or replacement. 13.6V Supply provides 13.6-volts at 10A with overload protection at 12A (Max).
CAUTION. USE THIS MODE WITH EXTREME CARE. SUPPLY MODE DISABLES SAFETY FEATURES AND LIVE POWER IS PRESENT AT THE CONNECTORS. DO NOT TOUCH CONNECTIONS TOGETHER. RISK OF SPARKS, FIRE, EXPLOSION, PROPERTY DAMAGE, INJURY, AND DEATH.

Using 12V Repair. [From Standby Press and Hold 3 Seconds With Clamps Connected to the Battery]
12V Repair is an advanced battery recovery mode for repairing and storing, old, idle, damaged, stratified or sulfated batteries. Not all batteries can be recovered. Batteries tend to become damaged if kept at a low charge and/or never given the opportunity to receive a full charge. The most common battery problems are battery sulfation and stratification. Both battery sulfation and stratification will artificially raise the open circuit voltage of the battery, causing the battery to appear fully charged, while providing low capacity. Use 12V Repair in attempt to reverse these problems. For optimal results, take the 12-volt battery through a full charge cycle, bringing the battery to full charge, before using this mode. 12V Repair can take up to four (4) hours to complete the recovery process and will return to Standby when completed.
CAUTION. USE THIS MODE WITH CARE. THIS MODE IS FOR 12-VOLT LEAD-ACID BATTERIES ONLY. THIS MODE USES A HIGH CHARGING VOLTAGE AND MAY CAUSE SOME WATER LOSS IN WET (FLOODED) CELL BATTERIES. BE ADVISED, SOME BATTERIES AND ELECTRONICS MAY BE SENSITIVE TO HIGH CHARGING VOLTAGES. TO MINIMIZE RISKS TO ELECTRONICS, DISCONNECT THE BATTERY BEFORE USING THIS MODE.

Force Mode. [Press & Hold for 5 seconds]
Force mode allow the charger to manually begin charging when the connected battery’s voltage is too low to be detected. If battery voltage is too low for the charger to detect, press and hold the mode button for 5 seconds to activate Force Mode, then select the appropriate mode. All available modes will flash. Once a charge mode is selected, the Charge Mode LED and Charge LED will alternate between each other, indicating Force Mode is active. After five (5) minutes the charger will return to the normal charge operation and low voltage detection will be reactivated.
CAUTION.USE THIS MODE WITH EXTREME CARE. FORCE MODE DISABLES SAFETY FEATURES AND LIVE POWER IS PRESENT AT THE CONNECTORS. ENSURE ALL CONNECTIONS ARE MADE PRIOR TO ENTERING FORCE MODE, AND DO NOT TOUCH CONNECTIONS TOGETHER. RISK OF SPARKS, FIRE, EXPLOSION, PROPERTY DAMAGE, INJURY, AND DEATH.

Connecting to the Battery.
Do not connect the AC power plug until all other connections are made. Identify the correct polarity of the battery terminals on the battery. Do not make any connections to the carburetor, fuel lines, or thin, sheet metal parts. The below instructions are for a negative ground system (most common). If your vehicle is a positive ground system (very uncommon), follow the below instructions in reverse order.

  1. Connect the positive (red) eyelet terminal connector to the positive (POS,P,+) battery terminal.
  2. Connect the negative (black) eyelet terminal connector to the negative (NEG,N,-) battery terminal.
  3. Connect the battery charger into a suitable electrical outlet. Do not face the battery when making this connection.
  4. When disconnecting, disconnect in the reverse sequence, removing the negative first (or positive first for positive ground systems).

Begin Charging.

  1. Verify the voltage and chemistry of the battery.
  2. Confirm that you have connected the battery clamps or eyelet terminal connectors properly and the AC power plug is plugged into an electrical outlet.
  3. [First time use] The charger will begin in Standby mode, indicated by an orange LED. In Standby, the charger is not providing any power.
  4. Press the mode button to toggle to the appropriate charge mode (press and hold for three seconds to enter an advanced charge mode) for the voltage and chemistry of your battery.
  5. The mode LED will illuminate the selected charge mode and the Charge LEDs will illuminate (depending on the health of the battery) indicating the charging process has started.
  6. The charger can now be left connected to the battery at all times to provide maintenance charging.

Auto-Memory: The charger has built in auto-memory and will return to the last charge mode when connected. To change modes after the first use, press the mode button.

Charging Times.

The estimated time to charge a battery is shown below. The size of the battery (Ah) and its depth of discharge (DOD) greatly affect its charging time. The charge time is based on an average depth of discharge to a fully charged battery and is for reference purposes only. Actual data may differ due to battery conditions. The time to charge a normally discharged battery is based on a 50% DOD. Temperature will also impact charging times. The GENIUS10 features thermal compensation that automatically adjusts charging profiles to maximize charging performance.

Understanding error leds

Error Conditions will be indicated by the following LEDs.

LED Reason/Solution
Power led Charger is in Standby mode or Battery voltage is too low for charger to detect.
Over Voltage led  Battery voltage is too high for the selected charge mode. Check the battery and charge mode.
Bad battery led Possible battery short / Battery will not hold a charge. Have battery checked by a professional.
Reserve polarity led Reverse polarity detected. Reverse the battery connections.
All error led flashing Charger internal temperature too high / Charger will resume function once the Charger internal temperature drops.
Charger ambient temperature too cold / Charger will resume function once the Charger ambient temperature rises.

Download Noco Genius10 Smart Charger User Guide

Noco Genius10 Smart Charger User Guide PDF manual download - Free user guide from GManuals
Brand Noco
Model Genius10
Category Battery Charger

File Size 85.42 Kb
Pages 11 pages
Language English
5648 views

Please read instruction before using the product. Detailed instruction can be found in Noco Genius10 User Guide that you can download PDF file or read the user manual online in the link provided above

1 Comments

  • 
                      ultimateshop vc avatar ultimateshop vc :

    Write more, thats all I have to say. Literally, it seems as though you relied on the video to
    make your point. You obviously know what youre talking about, why throw away your intelligence on just posting videos to
    your blog when you could be giving us something enlightening to read?

Give a Review

(will not be published)


Are you human?